from Cooper Power Systems for S.T.A.R.™ Faulted Circuit Indicators PATHFINDER™ (Variable Trip Test Point Type)
The Variable Trip design eliminates the need to specify a trip rating for the FCI. The load sensing feature adjusts the FCI to normal load conditions. When a fault occurs, the unit senses the rise in system current caused by the fault, followed by the loss of system voltage due to operation of the protective device. Thus, the Variable Trip FCI provides a “one size fits all”FCI for voltage test points, reducing inventory and eliminating problems caused by misapplication of FCIs.
Cooper Power Systems S.T.A.R.™PATHFINDER™ Variable Trip Test Point faulted circuit indicators (FCI) are designed to quickly and easily locate faulted sections of underground cable systems. These FCIs can be used on both 200 A separable connectors and 600 A terminators with a voltage test point. The removable sleeve allows for use on major manufacturers’ loadbreak elbows.
The PATHFINDER Variable Trip Test Point FCI features a trip design that senses normal load current and indicates a fault when a significant rise in current, followed by a loss of voltage,is detected. Hence, there is no need to specify a particular trip rating when ordering the Variable Trip Test Point FCI. This design ensures fast, reliable and accurate operation.
A long-life Lithium Ion battery provides power to indicate the faulted conditions using a high intensity light-emitting diode (LED) display. The unit will flash for a period of four hours after a fault has occurred. After the four hour period, the LED will stop flashing to conserve battery power; however, the unit retains a record of the fault event,and can be interrogated after the four hour period, using the manual testing/reset tool. The unit retains the memory of the fault event until reset manually,or until normal system power is restored.
Variable Trip FCIs provide a reliable means of fault location and isolation.They also eliminate fault chasing methods that are costly and time consuming, and stressful on systemcomponents exposed to fault currents.
The Cooper Power Systems remote fiber optic display provides remote visual indication of the FCI operation. This display can be mounted in transformer and sector cabinets with a single hole installation. The remote fiber optic cable can be ordered using catalog number SFOC.
Auxiliary Contacts can be added to the standard unit and provide an additional data collection point when used on circuits connected to a SCADA system. The magnetic latching circuit that operates the auxiliary contact ensures a reliable indication.
advertisement
The Revised CHANCE® / Hubbell Power Systems Grounding Encyclopedia on temporary grounding for de-energized construction and maintenance, covers grounding practices; electrical current’s effects on humans; OSHA requirements; ASTM, IEEE and IEC standards; step- and touch-potential; equipotential zones; equipment and applications; and installation procedures for overhead, underground, substation and truck grounding.
Use this new web application tool to help you evaluate lightning performance for typical 34.5, 69, 138 and 230 kV lines.
Burns & McDonnell T&D Toolkit: A free resource of tools, calculators and charts to help you design your next T&D project.
T&D World University - Get the training you need without leaving your office.
Read past editions of Hubbell Tips & News