| Item | S.T.A.R.™ Faulted Circuit Indicators (Delayed Reset Type) |
| Company | Cooper Power Systems |
| Catalog Number | |
| Price | Request Quote |
| Quantity | 0 |
| Manufacturer's Comment | Cooper Power Systems S.T.A.R.™Delayed Reset (DR) faulted circuit indicators are designed to quickly and easily locate faulted sections of cable systems. These faulted circuit indicators (FCI) can be installed on padmounted distribution transformers,sector cabinets, switchgear and overhead bare conductors. A long-life Lithium Ion battery provides power to indicate the faulted conditions using a high intensity LED display. The unit automatically resets back to the normal position when reset time has expired. The unit can also be reset using the optional manual testing/reset tool. DR FCIs provide a reliable means of fault location and isolation. They also eliminate fault chasing methods that are costly and time consuming, and very stressful on system components exposed to fault currents. The DR FCI is ideally suited for temporary use as a testing tool. The delayed reset also allows the unit to be used to detect general fault location in applications where an intermittent fault causes recloser operation, but power is restored before the unit is interrogated. |
| Operating Temperature | -40°C to +85°C per ANSI/IEEE 495-1986 |
| Trip Current Level | Factory Preset (High or Low) |
| Trip Accuracy | ±10% |
| Fault Withstand | 10 kA for 10 Cycles per ANSI/IEEE 495-1986 |
| Battery | 1.2 AH Lithium Ion Battery (non-replaceable) |
| Options | Testing/Reset Tool The manual testing/reset tool can be ordered using catalog number SMRT. |
| flag/led | 800 Hours |
| More Information | Company Product Page |
| S.T.A.R. Delayed Reset fault indicators consist of a sensor unit with an integral high intensity LED display powered by a Lithium Ion battery. DR FCIs feature an economical reed switch design. Installation can be achieved on a wide range of cable diameters with a single hot stick. The sensor unit itself features a clamping mechanism design that allows easy snap-on connection to the live conductor with the use of a single shotgun stick. The S.T.A.R. Delayed Reset faulted circuit indicator automatically resets back to the normal position when the reset time has expired. The unit is available in factory preset delay times of 1, 2, 4, or 6 hours. The DR FCI is constructed using tough, durable, corrosion-proof, submersible materials. The Lithium Ion battery provides 800 hours of flashing time for the high intensity LED display. The quick response time of the S.T.A.R. Delayed Reset faulted circuit indicator provides easy coordination with current-limiting fuses and other protection devices.The unit is insensitive to primary line voltage and will operate on any cable system. This unique combination of standard features makes the S.T.A.R. faulted circuit indicator extremely reliable.Fault Indicators S.T.A.R.™ Faulted Circuit Indicators Delayed Reset Type Electrical Apparatus 320-65. |
| Request Quote |
1045 Hickory St Pewaukee, WI 53072 USA
|