from S&C Electric Company for S&C TripSaver™ Dropout Recloser(COMPLETE BRANCH-FEEDER STYLE TRIPSAVER WITH “K” SPEED CONTROL MODULE)
It’s ideally suited for protection of laterals that experience frequent momentary faults. This self-powered, electronically controlled, single-phase vacuum fault interrupter is available for installation in new or existing current-production (“R10”) S&C Type XS Fuse cutout mountings.A two-insulator, branch-feeder style mounting is also available.TripSaver eliminates the permanent outage which results when the lateral fuse operates in response to a momentary fault. Utilities using “fuse blowing” will see an improvement in SAIFI without sacrificing MAIFI and TripSaver eliminates the momentary interruption on the feeder in instances where the breaker is tripped to save the lateral fuse during a momentary fault. Utilities using “fuse saving” will see an improvement in MAIFI without sacrificing SAIFI.
TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.
Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E
advertisement
The Revised CHANCE® / Hubbell Power Systems Grounding Encyclopedia on temporary grounding for de-energized construction and maintenance, covers grounding practices; electrical current’s effects on humans; OSHA requirements; ASTM, IEEE and IEC standards; step- and touch-potential; equipotential zones; equipment and applications; and installation procedures for overhead, underground, substation and truck grounding.
Use this new web application tool to help you evaluate lightning performance for typical 34.5, 69, 138 and 230 kV lines.
Burns & McDonnell T&D Toolkit: A free resource of tools, calculators and charts to help you design your next T&D project.
T&D World University - Get the training you need without leaving your office.
Read past editions of Hubbell Tips & News