Description

It’s ideally suited for protection of laterals that experience frequent momentary faults. This self-powered, electronically controlled, single-phase vacuum fault interrupter is available for installation in new or existing current-production (“R10”) S&C Type XS Fuse cutout mountings.A two-insulator, branch-feeder style mounting is also available.TripSaver eliminates the permanent outage which results when the lateral fuse operates in response to a momentary fault. Utilities using “fuse blowing” will see an improvement in SAIFI without sacrificing MAIFI and TripSaver eliminates the momentary interruption on the feeder in instances where the breaker is tripped to save the lateral fuse during a momentary fault. Utilities using “fuse saving” will see an improvement in MAIFI without sacrificing SAIFI.

Construction
  • Birdproof-design insulator—higher insulation characteristics than ANSI distribution-cutout standards. Porcelain insulator shown; composite-polymer silicone insulator also available. NEMA Type B and extended mounting brackets are available too.
  • Parallel-groove connector—tin-plated cast red brass. For ease of connection, accommodates two conductors, even of unlike size.Other types of connectors are also available.
  • Upper contact—silver-to-silver; stainless-steel spring provides high contact pressure.
  • Rugged attachment hooks for Loadbuster—guide TripSaver during closing.
  • Vacuum fault interrupter.
  • Lower contacts (not visible)—silver-to-silver; provide dual current path,independent of hinge pivot
  • Trunnion—high-strength cast bronze, silver plated. Surfaces around trunnion bear on broad hinge surfaces to keep TripSaver in alignment during closing
  • Mode selector— for selecting automatic reclosing or non-reclosing operation. Non-reclosing mode has one-shot-to-lockout operation, suitable for use when crews are working downstream of the TripSaver.
  • Detailed Specifications
  • ItemS&C TripSaver™ Dropout Recloser(COMPLETE BRANCH-FEEDER STYLE TRIPSAVER WITH “K” SPEED CONTROL MODULE)
  • CompanyS&C Electric Company
  • PriceInquire
  • CatalogNumber199021-K050
  • Quantity0
  • nominal voltage15 kV
  • manufacturer's commentS&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

  • Maximum Continuous Current50 A,RMS
  • Maximum Interrupting Current (symmetrical)2000 A,RMS
  • Insulation material (i.e. oil, air epoxy?)Porcelain insulator and composite-polymer silicone insulator also available.
  • Standard bushing leakage distance to ground17 in.