Overhead Faulted Circuit Indicators

Compare and Learn about Overhead Faulted Circuit Indicators

Select up to 5 products from below to compare or request more information.
  • Continuous Withstand Load:
  • Operating Temperature: -40°C to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Factory Preset (High and Low)
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles per IEEE 495™ Std -1986 standard
  • Battery: 1000 hours continuous 2.4 Ah Lithium Ion Battery (Internal, non-replaceable).
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options: Can be equipped with an LED in addition to the Fis heye display.
  • manufacturer's comment: Cooper Power Systems S.T.A.R. Electrostatic Reset (ER) faulted circuit indicators are designed to quickly and easily locate faulted sections of overhead distribution systems. These faulted circuit indicators (FCIs) can be installed on overhead distribution lines and derive their power from the voltage gradient between the line and the ground plane. This voltage gradient provides a reliable source for operating and resetting the fault indicator when compared to current reset devices which are subject to system loading variations. Electrostatic Reset FCIs provide a reliable means of fault location and isolation. In addition, they eliminate fault chasing methods which are costly and time consuming, and very stressful on system components exposed to the fault currents. Electrostatic Reset fault indicators have been designed to operate primarily on uninsulated, unshielded cable but may also be used on an unshielded insulated cable such as tree wire.
Read More
Inquire
Compare for selected.
  • Continuous Withstand Load:
  • Operating Temperature: -40°C to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Factory Preset (High and Low)
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles per ANSI/IEEE 495-1986
  • Battery: Two 1.2 AH Lithium Ion Batteries (20 Year Shelf Life)
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Cooper Power Systems S.T.A.R.™Manual Reset (MR) faulted circuit indicators are designed to quickly and easily locate faulted sections of cable on distribution systems. These faulted circuit indicators (FCIs) can be installed on padmounted distribution transformers, sector cabinets,switchgear, and overhead distribution lines. Manual Reset FCIs provide a reliable means of fault location and isolation. In addition, they eliminate fault chasing methods which are costly and time consuming, and very stressful on system components exposed to the fault currents. Manual Reset faulted circuit indicators are designed to operate on overhead uninsulated,unshielded cable and unshielded insulated cable (such as tree wire), as well as concentric neutral and other cable, in underground, padmount and vault applications.
Read More
Inquire
Compare for selected.
  • Continuous Withstand Load:
  • Operating Temperature: -40°C to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: 100 A rise within 6-cycles
  • Trip Accuracy:
  • Fault Withstand: 25 kA for 10 cycles per ANSI®/IEEE 495-1986™
  • Battery:
    2.4 Ah Lithium Ion Battery (internal, non-replaceable)
    2.4 Ah Lithium Ion Battery (replaceable battery, optional)
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment:

    Cooper Power Systems S.T.A.R.™ PATHFINDER™ Variable Trip Electrostatic Reset faulted circuit indicators (FCI) are designed to quickly and easily locate faulted sections of overhead distribution systems. These FCIs can be installed on overhead uninsulated, unshielded cable, or unshielded insulated cable such as tree wire. The removable pads allow the Variable Trip Electrostatic Reset FCI to be used on a wide range of cable diameters.

    S.T.A.R. PATHFINDER Electrostatic Reset FCIs feature a voltage and current sensing design, which indicates a fault when a significant rise in current, followed by a loss of voltage, is detected. Hence, there is no need to specify a particular trip rating when ordering the PATHFINDER Electrostatic Reset FCI. This design ensures fast,reliable and accurate operation.

    A long-life Lithium Ion battery provides power to indicate the faulted conditions using a highly visible FISHEYE™display. The battery provides power to the FCI only when a fault occurs, turning the FISHEYE display. This ensures maximum battery life.

    The standard SEVT unit will remain in the tripped position for a period of four hours following restoration of normal system voltage after a fault has occurred. Reset times of 24-hours and 4-minutes are also available. This allows time for operators to interrogate the unit. After the factory-programmed reset period, the unit will return to the black or normal position. If the system power is not restored, the FCI remains in the tripped position indefinitely, but can be reset manually using the manual testing/reset tool, SMRT. The unit can also be manually reset following restoration of system power, before the reset time has expired.

    The PATHFINDER Electrostatic Reset FCI will reset automatically when installed on a live circuit. The unit can also be reset manually, and requires no charge-up time if installed on a de-energized circuit. Thus, the Variable Trip Type ER FCI is ideal for permanent installations, or as a temporary testtool.

Read More
Inquire
Compare for selected.

AutoRANGER™ Overhead, Variable Trip, Timed Reset: Type AR-OH

E O Schweitzer Manufacturing Division of SEL

  • Continuous Withstand Load:
  • Operating Temperature: Temperature Range: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level:
  • Trip Accuracy:
  • Fault Withstand: 25 kA for 10 cycles
  • Battery: 3.6 V high-capacity lithium battery with a 15 year life expectancy
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: The AutoRANGER is a self-adjusting fault indicator. It automatically selects one of eight discrete trip values based on the sampled load current of the circuit to which it is applied.
Read More
Compare or Request Quote for selected.

BEACON™ Electrostatic Reset: Type BER

E O Schweitzer Manufacturing Division of SEL

  • Continuous Withstand Load:
  • Operating Temperature: Temperature Range: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Nominal Trip Ratings: 50 to 1200 A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles at 60 Hz
  • Battery: 3.6 V high-capacity lithium battery with a 20-year shelf life
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment:

    Key Features

    • Dual-display FCI incorporates LED with a reflective red mechanical target (the largest in the industry) to provide excellent visual indication, even in low light conditions.
    • 1,200 flashing hours standard; 3,000 flashing hours with the nonreplaceable battery.
    • The mechanical target continues to provide indication regardless of battery status.
    • Automatic reset upon restoration of system voltage.
    • Daylight Restraint® conserves battery life by activating the LED only in reduced ambient light conditions.
    • Apply at strategic intervals along overhead conductors and at midfeeder disconnects to minimize fault-finding time and optimize reliability statistics.
    • Inrush restraint feature prevents false tripping during recloser operations.
    Read More
Compare or Request Quote for selected.

BEACON™ Field-Programmable Timed Reset: Type BTRIP

E O Schweitzer Manufacturing Division of SEL

  • Continuous Withstand Load:
  • Operating Temperature: Temperature Range: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Trip Ratings: Programmable options from 50 A to 1200 A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles
  • Battery: 3.6 V high-capacity 8.5 Ah lithium battery with a 20-year shelf life
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Use the CRSRTT tool (included) to program, field-test, and manually reset the BTRIP.
Read More
Compare or Request Quote for selected.

BEACON™ Timed Reset: Type BTRI_IR

E O Schweitzer Manufacturing Division of SEL

  • Continuous Withstand Load:
  • Operating Temperature: Temperature Range: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Nominal Trip Ratings: 50 to 1200 A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles at 60 Hz
  • Battery:

    Power Source: High-capacity 3.6 V lithium battery

    • Replaceable Battery: 1200-hour flashing life (2.4 Ah cell)
    • Nonreplaceable Battery: 3000-hour flashing life (8.5 Ah cell)
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Use the CRSRTT tool (sold separately) to field-test and manually reset the BTRI_IR.
Read More
Compare or Request Quote for selected.

Current Reset Type: Type 1CRD

E O Schweitzer Manufacturing Division of SEL

  • Continuous Withstand Load:
  • Operating Temperature: Temperature Range: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset: 3 A
  • Trip Current Level: Nominal Trip Ratings: 400 and 800 A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles
  • Battery: No battery necessary.
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: The CRD Fault Indicator is easy to install on an overhead line using a single hot stick.
Read More
Compare or Request Quote for selected.

Overhead Electrostatic Reset: Type ERL

E O Schweitzer Manufacturing Division of SEL

  • Continuous Withstand Load:
  • Operating Temperature: Temperature Range: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Nominal Trip Ratings: 50 to 1200 A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles at 60 Hz
  • Battery: No battery to replace or monitor.
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
    • "DT” 24 ms Delayed Trip
    • “CC” Constant Calibration
    • “S” Snap Action Clamp
    • Consult EOS for additional features
  • manufacturer's comment:

    Key Features

    • Automatically resets upon restoration of system voltage.
    • Applied at strategic intervals along overhead conductors and at midfeeder disconnects to minimize fault-finding time and optimize reliability statistics.
    • Inrush restraint feature prevents false tripping during recloser operations.
    • The reflective red target (the largest display in the industry) is easy to spot both at night and during the day.
    • Zero maintenance: no battery to replace or monitor.
    • Models with the snap action clamp option are applicable on live-front switchgear—simply install the ERL onto the barrel of the cable termination lug.
Read More
Compare or Request Quote for selected.
  • Continuous Withstand Load:
  • Operating Temperature:
    Sensor: -50°C to +90°C
    Indicator: -40°C to +85°C
  • Reset Time Accuracy:
  • Current Reset:
    • 1.625 in. sensor with U-lamination: 1.0 A
    • 2.1875 in. sensor with U-lamination 1.5 A
    • 1.625 in. sensor w/o U-lamination 2.0 A
    • 2.1875 in. sensor w/o U-lamination 3.0 A
  • Trip Current Level:
  • Trip Accuracy:
  • Fault Withstand: 25 kA for 10 cycles per ANSI/IEEE 495-1986
  • Battery: Lithium cell, 800 hours of operation, rated for 10 year life.
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment:

    Features

    • Reduces Inventory
    • Rate of Change Trip Function
    • Faulted Circuit Indicators instructions
    • Coordinates with Current-Limiting Fuses
    • Low Current Reset (1 Amp Available)
    • Flag-Type, High Intensity LED, or Fiber Optic Cable Display
    • SCADA Output
    • Integral Radio Transmitter Option
Read More
Compare or Request Quote for selected.
  • Continuous Withstand Load: 1000 A
  • Operating Temperature: Operating Temperature: -40° to +85°C
  • Reset Time Accuracy:
  • Current Reset: Factory preset for 1.2, 1.5, 3.0 and 5.0A
  • Trip Current Level: Factory preset from 50 to 1500A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles per
  • Battery:
    • Rated Battery Life: 10 years (long life lithium cell)

    • Model 1514B/1515B, - 800 hours of operation
      Model 1514D - 300 hours of operation
    • Flag/LED Operating Life @ 23°C:
    • Strobe Operating Life @ 23°C:
    • Radio Operating Life @ 23°C:
    • Conductor Diameter Range:
    • options:
      • Current Inrush Restraint: Avoids false trips caused by line energization or reclosure operations
      • Time-Delayed Reset: Offered with or without current reset override
      • Manual Reset: Available on all Series 1514 fault indicators
      • Flag or LED Display: Flag - Black (normal position), fluorescent orange (fault position). LED - Red, high intensity signal flashes every 2 seconds. (LED requires lithium battery)
      • SCADA: Latching or momentary N.C. output available with flag display. 3A @ 125 Vac, 250 Vac 1/10 HP @ 250 Vac.
      • Integral Radio Transmitter
      • Fiber Optics: A remote 10 ft. fiber optic cable display provides isolation for signal transmission of trip and reset operations.
    • manufacturer's comment:
      • Trip Current Rating - Selection of the trip current rating should be at least 3 times the expected full load current.
      • Reset Current Rating - Ensures reset on lightly loaded feeders. Use of a fault indicator with 1.2A reset is recommended
    Read More
Compare or Request Quote for selected.
  • Continuous Withstand Load: 1000 A
  • Operating Temperature: Operating Temperature: -40° to +85°C
  • Reset Time Accuracy: Reset Time Accuracy: +/- 10%
  • Current Reset:
    • 1548FH standard: 3 Amps Minimum
    • 1548GH special: 8 Amps Minimum
  • Trip Current Level: Fixed Trip Current Level: 50 to 1500A
  • Trip Accuracy: ±10%
  • Fault Withstand: 25 kA for 10 cycles (per ANSI/IEEE 495-1986)
  • Battery: Replaceable, 10+ yr Lithium Cell (Flag model non-replaceable)
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range: From 0.14 to 1.20 inches.
  • options:
    • Temporary/permanent fault indication.
    • Instantaneous recloser coordination feature.
    • Backfeed Restraint utilizing a delay trip scheme

    (requires protective device to pass 2 cycles minimum of fault current before closing).

  • manufacturer's comment:

    ACCESORIES:

    • Manual test and reset tool AT2186-10
    • Radio receivers
Read More
Compare or Request Quote for selected.

FCI 333 Series (LED Type 333-1, 333-4, 333-6)

Power Delivery Products Inc

  • Continuous Withstand Load:
  • Operating Temperature:
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: 60 amps to 2000 amps
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Armed and Ready.
Read More
Compare or Request Quote for selected.

FCI Load Tracker (Low Profile)

Power Delivery Products Inc

  • Continuous Withstand Load:
  • Operating Temperature:
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level:
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options: Low trip option
  • manufacturer's comment:
    • Self Powered
    • Easy to Install
Read More
Compare or Request Quote for selected.

Load Tracker (Directional Fault Indicator)

Power Delivery Products Inc

  • Continuous Withstand Load: 25,000 amps sym. RMS / 170 msec.
  • Operating Temperature: -40 to +85 ° C
  • Reset Time Accuracy:
  • Current Reset: 5 Amps Small Core / 10 Amps Large Core
  • Trip Current Level: 200A Min. to 3 to 5 Times Load (200A DEFAULT)
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range: 0.85 inches to 2.37 inches
  • options: Red or Green LED Fault Indication, Elbow or Cable Mounted
  • manufacturer's comment: Could be used in underground application too. Hotstick applied, one size fits all, close proximity immunity and automatic reset.
    • Automatic In-Rush Restraint
    • Load Tracking above 40 Amps
    • 900 flashing hours
    • One size for all circuits
    • Elbow or Cable Mounted
    • Lightweight = 10 ounces
    • Closed Core CT Design
    • Self Powered
    • Manual Test and Reset
    • Hot stick applied
    • 5 minute installation time
    • Self adjusting to load current
Read More
Compare or Request Quote for selected.

OH Load Tracker (Navigator Load Memory)

Power Delivery Products Inc

  • Continuous Withstand Load: 25,000 A / 1 second sym. RMS
  • Operating Temperature: -40 to +85 ° C
  • Reset Time Accuracy:
  • Current Reset: > 3 A load current
  • Trip Current Level: 100 amps
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range: 0.3 inches to 1.15 inches
  • options:
  • manufacturer's comment:
    • 72 Hour Hold High Load Memory
    • Highest Daytime Visibility
    • Low Battery Indication
    • Manual, Time and/or Current Reset

    The "X" signs in the catalog number are to be selected from multiple alternatives, and create a catalog number.
Read More
Compare or Request Quote for selected.
  • Continuous Withstand Load:
  • Operating Temperature:
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level:
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: FCI Navigator Radio Type FCI’s can be configured in a variety of ways to address phase reporting or three way group circuit reporting.
    • Transmitter Integral to FCI
    • Low Battery Remote Reporting
    • Communication Flexibility
Read More
Compare or Request Quote for selected.
  • Continuous Withstand Load:
  • Operating Temperature:
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level:
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment:
    • UG SCADA fault reporting
    • RTU Interface
    • Low Power Consumption
    • Economica
Read More
Compare or Request Quote for selected.

Overhead Line Fault Indicator

Thomas & Betts Corp, Utility Products Group

  • Continuous Withstand Load:
  • Operating Temperature: -40°CTo +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Low, 400 Amp; High, 800 Amp
  • Trip Accuracy:
  • Fault Withstand:
  • Battery: 3.6 volt Lithium Thyonil Chloride Battery
    Battery Capacity 2.4 Ah
    Battery Operating Life 1200 Flash Hours Minimum
    Battery Storage Life 15-20 Years
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Time Reset with LED Display Indicator auto-resets to normal after a four-hour time duration. Indicator may also be manually reset using an FTT test tool.
Read More
Inquire
Compare for selected.

Overhead Line Fault Indicator

Thomas & Betts Corp, Utility Products Group

  • Continuous Withstand Load:
  • Operating Temperature: -40°C To +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Low, 400 Amp; High, 800 Amp
  • Trip Accuracy:
  • Fault Withstand:
  • Battery:
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Voltage Reset with Flag Display. Indicator auto-resets to normal after system voltage restoration. Reset requires 5kV minimum voltage to operate. Reset operation time is proportional to system voltage.
Read More
Inquire
Compare for selected.

Overhead Line Fault Indicator

Thomas & Betts Corp, Utility Products Group

  • Continuous Withstand Load:
  • Operating Temperature: -40°C To +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Low, 400 Amp; High, 800 Amp
  • Trip Accuracy:
  • Fault Withstand:
  • Battery: 3.6 volt Lithium Thyonil Chloride Battery
    Battery Capacity 2.4 Ah
    Battery Operating Life 1200 Flash Hours Minimum
    Battery Storage Life 15-20 Years
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Voltage Reset with LED Display. Indicator auto-resets to normal after system voltage restoration. Reset requires 5kV minimum voltage to operate. Reset operation time is proportional to system voltage.
Read More
Inquire
Compare for selected.

Overhead Line Fault Indicator

Thomas & Betts Corp, Utility Products Group

  • Continuous Withstand Load:
  • Operating Temperature: -40°C To +85°C
  • Reset Time Accuracy:
  • Current Reset:
  • Trip Current Level: Low, 400 Amp; High, 800 Amp
  • Trip Accuracy:
  • Fault Withstand:
  • Battery: 3.6 volt Lithium Thyonil Chloride Battery
    Battery Capacity 2.4 Ah
    Battery Operating Life 1200 Flash Hours Minimum
    Battery Storage Life 15-20 Years
  • Flag/LED Operating Life @ 23°C:
  • Strobe Operating Life @ 23°C:
  • Radio Operating Life @ 23°C:
  • Conductor Diameter Range:
  • options:
  • manufacturer's comment: Voltage Operated, Time Reset, LED Display Indicator auto-resets after a four-hour time duration. Longer time resets are available upon request.
Read More
Inquire
Compare for selected.