  • Flashover Voltage (60Hz), Dry(Kv): 310
  • Flashover Voltage (60Hz), Wet(Kv) : 295
  • Positive Critical Impulse Flashover: 505 kV
  • Horizontal Coupling Length:
  • Leakage : 76 In. (1930 mm)
  • Strike / Dry Arc Distance: 30.7 In. (780 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End): Y-Clevis -52.5 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 370
  • Flashover Voltage (60Hz), Wet(Kv) : 350
  • Positive Critical Impulse Flashover: 605 kV
  • Horizontal Coupling Length:
  • Leakage : 92 In. (2337 mm)
  • Strike / Dry Arc Distance: 36.8 In. (935 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End): Y-Clevis -52.5 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 430
  • Flashover Voltage (60Hz), Wet(Kv) : 405
  • Positive Critical Impulse Flashover: 700 kV
  • Horizontal Coupling Length:
  • Leakage : 107 In. (2718 mm)
  • Strike / Dry Arc Distance: 42.9 In. (1090 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End): Y-Clevis -52.5 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 310
  • Flashover Voltage (60Hz), Wet(Kv) : 295
  • Positive Critical Impulse Flashover: 505 kV
  • Horizontal Coupling Length:
  • Leakage : 76 In. (1930 mm)
  • Strike / Dry Arc Distance: 30.7 In. (780 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End): Y-Clevis -52.5 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 370
  • Flashover Voltage (60Hz), Wet(Kv) : 350
  • Positive Critical Impulse Flashover: 605 kV
  • Horizontal Coupling Length:
  • Leakage : 92 In. (2337 mm)
  • Strike / Dry Arc Distance: 36.8 In. (935 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End): Y-Clevis -52.5 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 430
  • Flashover Voltage (60Hz), Wet(Kv) : 405
  • Positive Critical Impulse Flashover: 700 kV
  • Horizontal Coupling Length:
  • Leakage : 107 In. (2718 mm)
  • Strike / Dry Arc Distance: 42.9 In. (1090 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End): Y-Clevis -52.5 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 430
  • Flashover Voltage (60Hz), Wet(Kv) : 400
  • Positive Critical Impulse Flashover: 700 kV
  • Horizontal Coupling Length:
  • Leakage : 106 In. (2692 mm)
  • Strike / Dry Arc Distance: 42.9 In. (1090 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50,000 lbs. 222 kN
  • Routine Test Load (RTL): 25,000 lbs. 111 kN
  • End Fitting Type (Top/Structure End): Chain Eye -52.11 Ball. End fittings are steel or ductile iron. The compact Corona Shielding Ring (CSR) provides both electrical stress relief and a mechanical seal at the housing-to-end fitting interface.
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 335
  • Flashover Voltage (60Hz), Wet(Kv) : 265
  • Positive Critical Impulse Flashover: 535 kV
  • Horizontal Coupling Length:
  • Leakage : 2461 (96.9) mm (In.)
  • Strike / Dry Arc Distance: 815 (32.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 370
  • Flashover Voltage (60Hz), Wet(Kv) : 300
  • Positive Critical Impulse Flashover: 600 kV
  • Horizontal Coupling Length:
  • Leakage : 2794 (110.0) mm (In.)
  • Strike / Dry Arc Distance: 917 (36.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 415
  • Flashover Voltage (60Hz), Wet(Kv) : 335
  • Positive Critical Impulse Flashover: 660 kV
  • Horizontal Coupling Length:
  • Leakage : 3127 (123.1) mm (In.)
  • Strike / Dry Arc Distance: 1021 (40.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 335
  • Flashover Voltage (60Hz), Wet(Kv) : 265
  • Positive Critical Impulse Flashover: 535 kV
  • Horizontal Coupling Length:
  • Leakage : 2461 (96.9) mm (In.)
  • Strike / Dry Arc Distance: 815 (32.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 370
  • Flashover Voltage (60Hz), Wet(Kv) : 300
  • Positive Critical Impulse Flashover: 600 kV
  • Horizontal Coupling Length:
  • Leakage : 2794 (110.0) mm (In.)
  • Strike / Dry Arc Distance: 917 (36.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 415
  • Flashover Voltage (60Hz), Wet(Kv) : 335
  • Positive Critical Impulse Flashover: 660 kV
  • Horizontal Coupling Length:
  • Leakage : 3127 (123.1) mm (In.)
  • Strike / Dry Arc Distance: 1021 (40.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 335
  • Flashover Voltage (60Hz), Wet(Kv) : 265
  • Positive Critical Impulse Flashover: 535 kV
  • Horizontal Coupling Length:
  • Leakage : 2461 (96.9) mm (In.)
  • Strike / Dry Arc Distance: 815 (32.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 90 kN (20,000 lbs.)
  • Routine Test Load (RTL): 45 kN (10,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 370
  • Flashover Voltage (60Hz), Wet(Kv) : 300
  • Positive Critical Impulse Flashover: 600 kV
  • Horizontal Coupling Length:
  • Leakage : 2794 (110.0) mm (In.)
  • Strike / Dry Arc Distance: 917 (36.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 90 kN (20,000 lbs.)
  • Routine Test Load (RTL): 45 kN (10,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 415
  • Flashover Voltage (60Hz), Wet(Kv) : 335
  • Positive Critical Impulse Flashover: 660 kV
  • Horizontal Coupling Length:
  • Leakage : 3127 (123.1) mm (In.)
  • Strike / Dry Arc Distance: 1021 (40.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 90 kN (20,000 lbs.)
  • Routine Test Load (RTL): 45 kN (10,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 374
  • Flashover Voltage (60Hz), Wet(Kv) : 337
  • Positive Critical Impulse Flashover: 609 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 38 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 442
  • Flashover Voltage (60Hz), Wet(Kv) : 388
  • Positive Critical Impulse Flashover: 713 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 45 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 442
  • Flashover Voltage (60Hz), Wet(Kv) : 388
  • Positive Critical Impulse Flashover: 713 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 45 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 390
  • Flashover Voltage (60Hz), Wet(Kv) : 349
  • Positive Critical Impulse Flashover: 633 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 40 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 449
  • Flashover Voltage (60Hz), Wet(Kv) : 393
  • Positive Critical Impulse Flashover: 724 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 46 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 449
  • Flashover Voltage (60Hz), Wet(Kv) : 393
  • Positive Critical Impulse Flashover: 724 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 46 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 419
  • Flashover Voltage (60Hz), Wet(Kv) : 371
  • Positive Critical Impulse Flashover: 678 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 43 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 222 kN (50,000 lbs.)
  • Routine Test Load (RTL): 111 kN (25,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 360
  • Flashover Voltage (60Hz), Wet(Kv) : 325
  • Positive Critical Impulse Flashover: 623 kV
  • Horizontal Coupling Length:
  • Leakage : 9.1 [4.1] In. [mm]
  • Strike / Dry Arc Distance: 36.3 [922] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36 klb)
  • Routine Test Load (RTL): 80 kN (18 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 360
  • Flashover Voltage (60Hz), Wet(Kv) : 325
  • Positive Critical Impulse Flashover: 623 kV
  • Horizontal Coupling Length:
  • Leakage : 12.1 [5.5] In. [mm]
  • Strike / Dry Arc Distance: 36.3 [922] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36 klb)
  • Routine Test Load (RTL): 80 kN (18 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 360
  • Flashover Voltage (60Hz), Wet(Kv) : 325
  • Positive Critical Impulse Flashover: 623 kV
  • Horizontal Coupling Length:
  • Leakage : 15.6 [7.1] In. [mm]
  • Strike / Dry Arc Distance: 36.3 [922] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36 klb)
  • Routine Test Load (RTL): 80 kN (18 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 398
  • Flashover Voltage (60Hz), Wet(Kv) : 358
  • Positive Critical Impulse Flashover: 686 kV
  • Horizontal Coupling Length:
  • Leakage : 9.0 [4.1] In. [mm]
  • Strike / Dry Arc Distance: 40.3 [1024] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36 klb)
  • Routine Test Load (RTL): 80 kN (18 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 398
  • Flashover Voltage (60Hz), Wet(Kv) : 358
  • Positive Critical Impulse Flashover: 686 kV
  • Horizontal Coupling Length:
  • Leakage : 12.0 [5.4] In. [mm]
  • Strike / Dry Arc Distance: 40.3 [1024] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36 klb)
  • Routine Test Load (RTL): 80 kN (18 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 398
  • Flashover Voltage (60Hz), Wet(Kv) : 358
  • Positive Critical Impulse Flashover: 686 kV
  • Horizontal Coupling Length:
  • Leakage : 12.6 [5.7] In. [mm]
  • Strike / Dry Arc Distance: 40.3 [1024] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36 klb)
  • Routine Test Load (RTL): 80 kN (18 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S1 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 375
  • Flashover Voltage (60Hz), Wet(Kv) : 338
  • Positive Critical Impulse Flashover: 648 kV
  • Horizontal Coupling Length:
  • Leakage : 78.9 [2004] In. [mm]
  • Strike / Dry Arc Distance: 37.9 [963] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (25 klb)
  • Routine Test Load (RTL): 60 kN (12.5 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S1 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 375
  • Flashover Voltage (60Hz), Wet(Kv) : 338
  • Positive Critical Impulse Flashover: 648 kV
  • Horizontal Coupling Length:
  • Leakage : 121.5 [3086] In. [mm]
  • Strike / Dry Arc Distance: 37.9 [963] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (25 klb)
  • Routine Test Load (RTL): 60 kN (12.5 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S1 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 375
  • Flashover Voltage (60Hz), Wet(Kv) : 338
  • Positive Critical Impulse Flashover: 648 kV
  • Horizontal Coupling Length:
  • Leakage : 140.9 [3579] In. [mm]
  • Strike / Dry Arc Distance: 37.9 [963] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (25 klb)
  • Routine Test Load (RTL): 60 kN (12.5 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S1 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 413
  • Flashover Voltage (60Hz), Wet(Kv) : 372
  • Positive Critical Impulse Flashover: 712 kV
  • Horizontal Coupling Length:
  • Leakage : 79.1 [2009] In. [mm]
  • Strike / Dry Arc Distance: 42.9 [1090] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (25 klb)
  • Routine Test Load (RTL): 60 kN (12.5 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S1 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 413
  • Flashover Voltage (60Hz), Wet(Kv) : 372
  • Positive Critical Impulse Flashover: 712 kV
  • Horizontal Coupling Length:
  • Leakage : 117.8 [2992] In. [mm]
  • Strike / Dry Arc Distance: 42.9 [1090] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (25 klb)
  • Routine Test Load (RTL): 60 kN (12.5 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S1 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 413
  • Flashover Voltage (60Hz), Wet(Kv) : 372
  • Positive Critical Impulse Flashover: 712 kV
  • Horizontal Coupling Length:
  • Leakage : 144.9 [3680] In. [mm]
  • Strike / Dry Arc Distance: 42.9 [1090] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (25 klb)
  • Routine Test Load (RTL): 60 kN (12.5 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S2 Series Suspension Insulators

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 422
  • Flashover Voltage (60Hz), Wet(Kv) : 379
  • Positive Critical Impulse Flashover: 726 kV
  • Horizontal Coupling Length:
  • Leakage : 75.9 [1928] In. [mm]
  • Strike / Dry Arc Distance: 42.8 [1087] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 210 kN (50 klb)
  • Routine Test Load (RTL): 105 kN (25 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S2 Series Suspension Insulators

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 422
  • Flashover Voltage (60Hz), Wet(Kv) : 379
  • Positive Critical Impulse Flashover: 726 kV
  • Horizontal Coupling Length:
  • Leakage : 118.0 [2997] In. [mm]
  • Strike / Dry Arc Distance: 42.8 [1087] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 210 kN (50 klb)
  • Routine Test Load (RTL): 105 kN (25 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S2 Series Suspension Insulators

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 422
  • Flashover Voltage (60Hz), Wet(Kv) : 379
  • Positive Critical Impulse Flashover: 726 kV
  • Horizontal Coupling Length:
  • Leakage : 144.9 [3680] In. [mm]
  • Strike / Dry Arc Distance: 42.8 [1087] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 210 kN (50 klb)
  • Routine Test Load (RTL): 105 kN (25 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S5 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 357
  • Flashover Voltage (60Hz), Wet(Kv) : 322
  • Positive Critical Impulse Flashover: 617 kV
  • Horizontal Coupling Length:
  • Leakage : 76.9 [1953] In. [mm]
  • Strike / Dry Arc Distance: 36.0 [914] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30 klb)
  • Routine Test Load (RTL): 66.5 kN (15 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S5 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 357
  • Flashover Voltage (60Hz), Wet(Kv) : 322
  • Positive Critical Impulse Flashover: 617 kV
  • Horizontal Coupling Length:
  • Leakage : 119.4 [3033] In. [mm]
  • Strike / Dry Arc Distance: 36.0 [914] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30 klb)
  • Routine Test Load (RTL): 66.5 kN (15 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S5 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 357
  • Flashover Voltage (60Hz), Wet(Kv) : 322
  • Positive Critical Impulse Flashover: 617 kV
  • Horizontal Coupling Length:
  • Leakage : 155.3 [3945] In. [mm]
  • Strike / Dry Arc Distance: 36.0 [914] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30 klb)
  • Routine Test Load (RTL): 66.5 kN (15 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S5 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 395
  • Flashover Voltage (60Hz), Wet(Kv) : 356
  • Positive Critical Impulse Flashover: 681 kV
  • Horizontal Coupling Length:
  • Leakage : 77.0 [1956] In. [mm]
  • Strike / Dry Arc Distance: 40.0 [1016] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30 klb)
  • Routine Test Load (RTL): 66.5 kN (15 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S5 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 395
  • Flashover Voltage (60Hz), Wet(Kv) : 356
  • Positive Critical Impulse Flashover: 681 kV
  • Horizontal Coupling Length:
  • Leakage : 119.6 [3038] In. [mm]
  • Strike / Dry Arc Distance: 40.0 [1016] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30 klb)
  • Routine Test Load (RTL): 66.5 kN (15 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.

S5 Series Suspension Insulator

MacLean Power Systems

  • Flashover Voltage (60Hz), Dry(Kv): 395
  • Flashover Voltage (60Hz), Wet(Kv) : 356
  • Positive Critical Impulse Flashover: 681 kV
  • Horizontal Coupling Length:
  • Leakage : 146.9 [3731] In. [mm]
  • Strike / Dry Arc Distance: 40.0 [1016] In. [mm]
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30 klb)
  • Routine Test Load (RTL): 66.5 kN (15 klbs.)
  • End Fitting Type (Top/Structure End):
    • Ball EF on Line End
    • Y-Clevis EF on Tower End
  • Weathershed / Sheath Material: Rubber and RTV Silicone
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 385
  • Flashover Voltage (60Hz), Wet(Kv) : 340
  • Positive Critical Impulse Flashover: 585 kV
  • Horizontal Coupling Length:
  • Leakage : 94.5 In. (2401 mm)
  • Strike / Dry Arc Distance: 35.1 In. (892 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25 (000' lbs.)
  • Routine Test Load (RTL): 50% of the SML
  • End Fitting Type (Top/Structure End): Y-clevis and Ball (ANSI J) type end fitting. Stainless steel and galvanized ductile iron. Water-tight sealing structure.
  • Weathershed / Sheath Material: Silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 380
  • Flashover Voltage (60Hz), Wet(Kv) : 340
  • Positive Critical Impulse Flashover: 580 kV
  • Horizontal Coupling Length:
  • Leakage : 78.3 In. (1988 mm)
  • Strike / Dry Arc Distance: 34.8 In. (884 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25 (000' lbs.)
  • Routine Test Load (RTL): 50% of the SML
  • End Fitting Type (Top/Structure End): Y-clevis and Ball (ANSI J) type end fitting. Stainless steel and galvanized ductile iron. Water-tight sealing structure.
  • Weathershed / Sheath Material: Silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 380
  • Flashover Voltage (60Hz), Wet(Kv) : 340
  • Positive Critical Impulse Flashover: 580 kV
  • Horizontal Coupling Length:
  • Leakage : 78.3 In. (1988 mm)
  • Strike / Dry Arc Distance: 34.8 In. (884 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30(000' lbs.)
  • Routine Test Load (RTL): 50% of the SML
  • End Fitting Type (Top/Structure End): Y-clevis and Ball (ANSI J) type end fitting. Stainless steel and galvanized ductile iron. Water-tight sealing structure.
  • Weathershed / Sheath Material: Silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 380
  • Flashover Voltage (60Hz), Wet(Kv) : 340
  • Positive Critical Impulse Flashover: 580 kV
  • Horizontal Coupling Length:
  • Leakage : 78.3 In. (1988 mm)
  • Strike / Dry Arc Distance: 47.8 In. (1214 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50(000' lbs.)
  • Routine Test Load (RTL): 50% of the SML
  • End Fitting Type (Top/Structure End): Y-clevis and Ball (ANSI K) type end fitting. Stainless steel and galvanized ductile iron. Water-tight sealing structure.
  • Weathershed / Sheath Material: Silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 415
  • Flashover Voltage (60Hz), Wet(Kv) : 365
  • Positive Critical Impulse Flashover: 635 kV
  • Horizontal Coupling Length:
  • Leakage : 86.7 In. (2201 mm)
  • Strike / Dry Arc Distance: 54.9 In. (1394 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50(000' lbs.)
  • Routine Test Load (RTL): 50% of the SML
  • End Fitting Type (Top/Structure End): Y-clevis and Ball (ANSI K) type end fitting. Stainless steel and galvanized ductile iron. Water-tight sealing structure.
  • Weathershed / Sheath Material: Silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 415
  • Flashover Voltage (60Hz), Wet(Kv) : 365
  • Positive Critical Impulse Flashover: 635 kV
  • Horizontal Coupling Length:
  • Leakage : 86.7 In. (2201 mm)
  • Strike / Dry Arc Distance: 38.3 In. (974 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25 (000' lbs.)
  • Routine Test Load (RTL): 50% of the SML
  • End Fitting Type (Top/Structure End): Y-clevis and Ball (ANSI J) type end fitting. Stainless steel and galvanized ductile iron. Water-tight sealing structure.
  • Weathershed / Sheath Material: Silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
Select up to 5 products from above to compare or request more information.
Showing 50 of 80 products.

Tags:

Please Login or Register to Create Tags