  • Flashover Voltage (60Hz), Dry(Kv): 655
  • Flashover Voltage (60Hz), Wet(Kv) : 605
  • Positive Critical Impulse Flashover: 1080 kV
  • Horizontal Coupling Length:
  • Leakage : 168 In. (4267 mm)
  • Strike / Dry Arc Distance: 67.4 In. (1712 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 655
  • Flashover Voltage (60Hz), Wet(Kv) : 605
  • Positive Critical Impulse Flashover: 1080 kV
  • Horizontal Coupling Length:
  • Leakage : 168 In. (4267 mm)
  • Strike / Dry Arc Distance: 67.4 In. (1712 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 710
  • Flashover Voltage (60Hz), Wet(Kv) : 655
  • Positive Critical Impulse Flashover: 1170 kV
  • Horizontal Coupling Length:
  • Leakage : 184 In. (4674 mm)
  • Strike / Dry Arc Distance: 73.5 In. (1867 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 710
  • Flashover Voltage (60Hz), Wet(Kv) : 655
  • Positive Critical Impulse Flashover: 1170 kV
  • Horizontal Coupling Length:
  • Leakage : 184 In. (4674 mm)
  • Strike / Dry Arc Distance: 73.5 In. (1867 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 760
  • Flashover Voltage (60Hz), Wet(Kv) : 700
  • Positive Critical Impulse Flashover: 1260 kV
  • Horizontal Coupling Length:
  • Leakage : 198 In. (5029 mm)
  • Strike / Dry Arc Distance: 79.5 In. (2019 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 760
  • Flashover Voltage (60Hz), Wet(Kv) : 700
  • Positive Critical Impulse Flashover: 1260 kV
  • Horizontal Coupling Length:
  • Leakage : 198 In. (5029 mm)
  • Strike / Dry Arc Distance: 79.5 In. (2019 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 810
  • Flashover Voltage (60Hz), Wet(Kv) : 750
  • Positive Critical Impulse Flashover: 1350 kV
  • Horizontal Coupling Length:
  • Leakage : 214 In. (5436 mm)
  • Strike / Dry Arc Distance: 85.6 In. (2174 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 810
  • Flashover Voltage (60Hz), Wet(Kv) : 750
  • Positive Critical Impulse Flashover: 1350 kV
  • Horizontal Coupling Length:
  • Leakage : 214 In. (5436 mm)
  • Strike / Dry Arc Distance: 85.6 In. (2174 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 855
  • Flashover Voltage (60Hz), Wet(Kv) : 790
  • Positive Critical Impulse Flashover: 1440 kV
  • Horizontal Coupling Length:
  • Leakage : 229 In. (5817 mm)
  • Strike / Dry Arc Distance: 91.7 In. (2329 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 30,000 lbs. 133 kN
  • Routine Test Load (RTL): 15,000 lbs. 67 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 855
  • Flashover Voltage (60Hz), Wet(Kv) : 790
  • Positive Critical Impulse Flashover: 1440 kV
  • Horizontal Coupling Length:
  • Leakage : 229 In. (5817 mm)
  • Strike / Dry Arc Distance: 91.7 In. (2329 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 25,000 lbs. 111 kN
  • Routine Test Load (RTL): 12,500 lbs. 56 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 600
  • Flashover Voltage (60Hz), Wet(Kv) : 555
  • Positive Critical Impulse Flashover: 985 kV
  • Horizontal Coupling Length:
  • Leakage : 151 In. (3835 mm)
  • Strike / Dry Arc Distance: 61.2 In. (1554 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50,000 lbs. 222 kN
  • Routine Test Load (RTL): 25,000 lbs. 111 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 655
  • Flashover Voltage (60Hz), Wet(Kv) : 605
  • Positive Critical Impulse Flashover: 1080 kV
  • Horizontal Coupling Length:
  • Leakage : 167 In. (4242 mm)
  • Strike / Dry Arc Distance: 67.3 In. (1709 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50,000 lbs. 222 kN
  • Routine Test Load (RTL): 25,000 lbs. 111 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 760
  • Flashover Voltage (60Hz), Wet(Kv) : 700
  • Positive Critical Impulse Flashover: 1260 kV
  • Horizontal Coupling Length:
  • Leakage : 197 In. (5004 mm)
  • Strike / Dry Arc Distance: 79.5 In. (2019 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50,000 lbs. 222 kN
  • Routine Test Load (RTL): 25,000 lbs. 111 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 810
  • Flashover Voltage (60Hz), Wet(Kv) : 745
  • Positive Critical Impulse Flashover: 1350 kV
  • Horizontal Coupling Length:
  • Leakage : 212 In. (5385 mm)
  • Strike / Dry Arc Distance: 85.6 In. (2174 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50,000 lbs. 222 kN
  • Routine Test Load (RTL): 25,000 lbs. 111 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 855
  • Flashover Voltage (60Hz), Wet(Kv) : 790
  • Positive Critical Impulse Flashover: 1440 kV
  • Horizontal Coupling Length:
  • Leakage : 228 In. (5791 mm)
  • Strike / Dry Arc Distance: 91.7 In. (2329 mm)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 50,000 lbs. 222 kN
  • Routine Test Load (RTL): 25,000 lbs. 111 kN
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: ESP compound. Housings manufactured with ESP silicone alloy rubber. Exhibits hydrophobicity, high mechanical strength, high corona resistance and low permeability to moisture.
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 695
  • Flashover Voltage (60Hz), Wet(Kv) : 570
  • Positive Critical Impulse Flashover: 1095 kV
  • Horizontal Coupling Length:
  • Leakage : 5456 (214.8) mm (In.)
  • Strike / Dry Arc Distance: 1730 (68.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 745
  • Flashover Voltage (60Hz), Wet(Kv) : 605
  • Positive Critical Impulse Flashover: 1160 kV
  • Horizontal Coupling Length:
  • Leakage : 5789 (227.9) mm (In.)
  • Strike / Dry Arc Distance: 1834 (72.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 785
  • Flashover Voltage (60Hz), Wet(Kv) : 645
  • Positive Critical Impulse Flashover: 1225 kV
  • Horizontal Coupling Length:
  • Leakage : 6121 (241.0) mm (In.)
  • Strike / Dry Arc Distance: 1935 (76.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 825
  • Flashover Voltage (60Hz), Wet(Kv) : 675
  • Positive Critical Impulse Flashover: 1285 kV
  • Horizontal Coupling Length:
  • Leakage : 6454 (254.1) mm (In.)
  • Strike / Dry Arc Distance: 2040 (80.3) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 120 kN (27,000 lbs.)
  • Routine Test Load (RTL): 60 kN (13,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 695
  • Flashover Voltage (60Hz), Wet(Kv) : 695
  • Positive Critical Impulse Flashover: 1095 kV
  • Horizontal Coupling Length:
  • Leakage : 5456 (214.8) mm (In.)
  • Strike / Dry Arc Distance: 1722 (67.8) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 745
  • Flashover Voltage (60Hz), Wet(Kv) : 745
  • Positive Critical Impulse Flashover: 1160 kV
  • Horizontal Coupling Length:
  • Leakage : 5789 (227.9) mm (In.)
  • Strike / Dry Arc Distance: 1824 (71.8) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 785
  • Flashover Voltage (60Hz), Wet(Kv) : 785
  • Positive Critical Impulse Flashover: 1225 kV
  • Horizontal Coupling Length:
  • Leakage : 6121 (241.0) mm (In.)
  • Strike / Dry Arc Distance: 1928 (75.9) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 825
  • Flashover Voltage (60Hz), Wet(Kv) : 825
  • Positive Critical Impulse Flashover: 1285 kV
  • Horizontal Coupling Length:
  • Leakage : 6454 (254.1) mm (In.)
  • Strike / Dry Arc Distance: 2040 (80.3) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 695
  • Flashover Voltage (60Hz), Wet(Kv) : 570
  • Positive Critical Impulse Flashover: 1095 kV
  • Horizontal Coupling Length:
  • Leakage : 5456 (214.8) mm (In.)
  • Strike / Dry Arc Distance: 1730 (68.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36,000 lbs.)
  • Routine Test Load (RTL): 80 kN (18,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 745
  • Flashover Voltage (60Hz), Wet(Kv) : 605
  • Positive Critical Impulse Flashover: 1160 kV
  • Horizontal Coupling Length:
  • Leakage : 5789 (227.9) mm (In.)
  • Strike / Dry Arc Distance: 1834 (72.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36,000 lbs.)
  • Routine Test Load (RTL): 80 kN (18,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 785
  • Flashover Voltage (60Hz), Wet(Kv) : 645
  • Positive Critical Impulse Flashover: 1225 kV
  • Horizontal Coupling Length:
  • Leakage : 6121 (241.0) mm (In.)
  • Strike / Dry Arc Distance: 1935 (76.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36,000 lbs.)
  • Routine Test Load (RTL): 80 kN (18,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 825
  • Flashover Voltage (60Hz), Wet(Kv) : 675
  • Positive Critical Impulse Flashover: 1285 kV
  • Horizontal Coupling Length:
  • Leakage : 6454 (254.1) mm (In.)
  • Strike / Dry Arc Distance: 2040 (80.3) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 160 kN (36,000 lbs.)
  • Routine Test Load (RTL): 80 kN (18,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 695
  • Flashover Voltage (60Hz), Wet(Kv) : 570
  • Positive Critical Impulse Flashover: 1095 kV
  • Horizontal Coupling Length:
  • Leakage : 5456 (214.8) mm (In.)
  • Strike / Dry Arc Distance: 1730 (68.1) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 90 kN (20,000 lbs.)
  • Routine Test Load (RTL): 45 kN (10,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 745
  • Flashover Voltage (60Hz), Wet(Kv) : 605
  • Positive Critical Impulse Flashover: 1160 kV
  • Horizontal Coupling Length:
  • Leakage : 5789 (227.9) mm (In.)
  • Strike / Dry Arc Distance: 1834 (72.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 90 kN (20,000 lbs.)
  • Routine Test Load (RTL): 45 kN (10,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 785
  • Flashover Voltage (60Hz), Wet(Kv) : 645
  • Positive Critical Impulse Flashover: 1225 kV
  • Horizontal Coupling Length:
  • Leakage : 6121 (241.0) mm (In.)
  • Strike / Dry Arc Distance: 1935 (76.2) mm (In.)
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 90 kN (20,000 lbs.)
  • Routine Test Load (RTL): 45 kN (10,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material:
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Inquire
Compare for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 720
  • Flashover Voltage (60Hz), Wet(Kv) : 598
  • Positive Critical Impulse Flashover: 1141 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 74 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 768
  • Flashover Voltage (60Hz), Wet(Kv) : 634
  • Positive Critical Impulse Flashover: 1215 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 79 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 768
  • Flashover Voltage (60Hz), Wet(Kv) : 634
  • Positive Critical Impulse Flashover: 1215 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 79 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 854
  • Flashover Voltage (60Hz), Wet(Kv) : 699
  • Positive Critical Impulse Flashover: 1347 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 88 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 854
  • Flashover Voltage (60Hz), Wet(Kv) : 699
  • Positive Critical Impulse Flashover: 1347 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 88 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 950
  • Flashover Voltage (60Hz), Wet(Kv) : 772
  • Positive Critical Impulse Flashover: 1495 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 98 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 950
  • Flashover Voltage (60Hz), Wet(Kv) : 772
  • Positive Critical Impulse Flashover: 1495 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 98 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 111 kN (25,000 lbs.)
  • Routine Test Load (RTL): 56 kN (12,500 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 726
  • Flashover Voltage (60Hz), Wet(Kv) : 603
  • Positive Critical Impulse Flashover: 1151 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 75 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 784
  • Flashover Voltage (60Hz), Wet(Kv) : 647
  • Positive Critical Impulse Flashover: 1240 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 81 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 784
  • Flashover Voltage (60Hz), Wet(Kv) : 647
  • Positive Critical Impulse Flashover: 1240 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 81 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 850
  • Flashover Voltage (60Hz), Wet(Kv) : 696
  • Positive Critical Impulse Flashover: 1342 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 87 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 850
  • Flashover Voltage (60Hz), Wet(Kv) : 696
  • Positive Critical Impulse Flashover: 1342 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 87 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 928
  • Flashover Voltage (60Hz), Wet(Kv) : 755
  • Positive Critical Impulse Flashover: 1461 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 95 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 133 kN (30,000 lbs.)
  • Routine Test Load (RTL): 67 kN (15,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 765
  • Flashover Voltage (60Hz), Wet(Kv) : 632
  • Positive Critical Impulse Flashover: 1210 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 79 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 222 kN (50,000 lbs.)
  • Routine Test Load (RTL): 111 kN (25,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 765
  • Flashover Voltage (60Hz), Wet(Kv) : 632
  • Positive Critical Impulse Flashover: 1210 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 79 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 222 kN (50,000 lbs.)
  • Routine Test Load (RTL): 111 kN (25,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 843
  • Flashover Voltage (60Hz), Wet(Kv) : 691
  • Positive Critical Impulse Flashover: 1330 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 87 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 222 kN (50,000 lbs.)
  • Routine Test Load (RTL): 111 kN (25,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 843
  • Flashover Voltage (60Hz), Wet(Kv) : 691
  • Positive Critical Impulse Flashover: 1330 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 87 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 222 kN (50,000 lbs.)
  • Routine Test Load (RTL): 111 kN (25,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 898
  • Flashover Voltage (60Hz), Wet(Kv) : 732
  • Positive Critical Impulse Flashover: 1415 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 92 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 222 kN (50,000 lbs.)
  • Routine Test Load (RTL): 111 kN (25,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 775
  • Flashover Voltage (60Hz), Wet(Kv) : 665
  • Positive Critical Impulse Flashover: 1285 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 80 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 445 kN (100,000 lbs.)
  • Routine Test Load (RTL): 222 kN (50,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment:
Read More
Compare or Request Quote for selected.
  • Flashover Voltage (60Hz), Dry(Kv): 910
  • Flashover Voltage (60Hz), Wet(Kv) : 730
  • Positive Critical Impulse Flashover: 1430 kV
  • Horizontal Coupling Length:
  • Leakage :
  • Strike / Dry Arc Distance: 90 In.
  • Specified Mechanical Load (SML) as Defined by ANSI C29.11-1989 (R1996): 445 kN (100,000 lbs.)
  • Routine Test Load (RTL): 222 kN (50,000 lbs.)
  • End Fitting Type (Top/Structure End):
  • Weathershed / Sheath Material: High Temperature Vulcanized (HTV) silicone rubber
  • Weathershed / Sheath Material Color:
  • manufacturer's comment: