Single,Electro,Vacuum Intake 15kV

Compare and Learn about Single,Electro,Vacuum Intake 15kV

Showing 50 of 54 products.
Select up to 5 products from below to compare or request more information.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 400/800 A
  • Maximum Interrupting Current (symmetrical): 6000/10000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Hydrophobic Cycloaliphatic Epoxy (HCEP)
  • Remote lockout indicator: Available
  • Standard bushing leakage distance to ground: 38.00 in. (960 mm)
  • Alternative bushing leakage distance to ground: 9.50 in. (240 mm)
  • Available factory installed accessories: Supported communications technologies include: Bushing Terminal connectorsand Block close
  • weight: 100 lbs. (45 kg)
  • Finish/color: Amber
  • manufacturer's comment: Benefits are:
    • Compact, lightweight design is easy to install, maneuver, and transport
    • Accurate coordination of down-line devices
    • Simple-to-program controller for easy training and maintenance
    • AC powered and does not require batteries
    • Optional battery back-up available
    • No electronics in high voltage cabinet protects controls from thermal overload
    • Allows for seamless communication integration with SCADA, modem, and radio systems
    • Available undervoltage trip/restore function - reduces the effects of cold load pick-ups
    • Electromechanical counter comes standard
    • Easily adaptable with surge arresters
    • 24 hour / 7 day dependable customer support

    No electronics in pole assembly leads to increased reliability and less raintenance. Long life with 10,000 operations. AC powered electronic control eliminates need for maintaining batteries. Simple programming from PC-based software.
Read More
Inquire
Compare for selected.
  • nominal voltage: 2.4 kV - 14.4 kV
  • Maximum Continuous Current: 630 A
  • Maximum Interrupting Current (symmetrical):
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
    • Weight (Mass) : 310 lbs. (140 kg) / 320 lbs. (145 kg)
    • Weight (Mass) with Pole Mounting Hanger : 425 lbs. (193 kg) / 435 lbs. (198 kg)
  • Finish/color:
  • manufacturer's comment: Each recloser is completely assembled, tested, and inspected at the factory. It is in good condition when accepted by the carrier for shipment. Upon receipt, inspect the shipping container for signs of damage. Unpack the recloser and inspect it thoroughly for damage incurred during shipment. If damage is discovered, file a claim with the carrier immediately.
Read More
Inquire
Compare for selected.

Kyle® Type Single-Phase Recloser

Cooper Power Systems

  • nominal voltage: 2.4 kV - 14.4 kV
  • Maximum Continuous Current: 400 A
  • Maximum Interrupting Current (symmetrical): 8000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Oil insulated
  • Remote lockout indicator: The 360° lockout indicator is viewable from all directions.
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment:

    The VXE recloser system successfully combine three technologies:

    • High-performance Kyle vacuum interrupter
    • Dependable low power mechanisms
    • Electronic and automated controls
Read More
Inquire
Compare for selected.

Kyle® Type Single-Phase Recloser

Cooper Power Systems

  • nominal voltage: 2.4 kV - 14.4 kV
  • Maximum Continuous Current: 400 A
  • Maximum Interrupting Current (symmetrical): 8000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator: The 360° lockout indicator is viewable from all directions.
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment:

    The NOVA1 recloser system successfully combine four technologies:

    • Cycloaliphatic-epoxy encapsulation
    • High-performance Kyle vacuum interrupter
    • Dependable low power mechanisms
    • Electronic and automated controls
Read More
Inquire
Compare for selected.

Kyle® Type Single-Phase Recloser

Cooper Power Systems

  • nominal voltage: 2.4 kV - 14.4 kV
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator: The 360° lockout indicator is viewable from all directions.
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment:

    The NOVA1 recloser system successfully combine four technologies:

    • Cycloaliphatic-epoxy encapsulation
    • High-performance Kyle vacuum interrupter
    • Dependable low power mechanisms
    • Electronic and automated controls
Read More
Inquire
Compare for selected.
  • nominal voltage:
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Solid dielectric insulated
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight: Weight (for a single phase module less bracket) : 125 lbs. (57 kg)
  • Finish/color: Painted with a Munsell 7.0GY3.29/1.5 green finish.
  • manufacturer's comment:

    Applications

    • Sectionalizing schemes
    • Distributed automatic transfer
    • Distribution automation
    • Circuit breaker alternative
    • Relay protection
    • Revenue grade metering
    • Open bus tie
Read More
Compare or Request Quote for selected.
  • nominal voltage: 14.4 kV
  • Maximum Continuous Current: 630 A or 800 A
  • Maximum Interrupting Current (symmetrical): 6000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Remote mounting control package, Pole-mounting bracket for the control, Shielded control cable with connectors on both ends, Specify length up to 40 feet and Arrester mounting provision for one arrester.
  • weight:
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1. Select voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Select control & mounting configuration.
    3. Specify cable length (Remote - Pole Mount only).
    4. Specify mounting frame.
    5. Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 14.4 kV
  • Maximum Continuous Current: 630 A or 800 A
  • Maximum Interrupting Current (symmetrical): 10000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Pole-mounting bracket for the control, Shielded control cable with connectors on both ends, Specify length up to 40 feet and Arrester mounting provision for one arrester.
  • weight:
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1. Select voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Select control & mounting configuration.
    3. Specify cable length (Remote - Pole Mount only).
    4. Specify mounting frame.
    5. Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 14.4 kV
  • Maximum Continuous Current: 630 A or 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Pole-mounting bracket for the control, Shielded control cable with connectors on both ends, Specify length up to 40 feet and Arrester mounting provision for one arrester.
  • weight:
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1. Select voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Select control & mounting configuration.
    3. Specify cable length (Remote - Pole Mount only).
    4. Specify mounting frame.
    5. Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 14.4 kV
  • Maximum Continuous Current: 630 A or 800 A
  • Maximum Interrupting Current (symmetrical): 6000 A RMS
  • load-interrupting current (asymmetrical): 42000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-651R Advanced Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frames and Extra creepage bushings
  • weight: 330 lbs. (150 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 600R Vacuum Recloser by selecting model number from the ratings table.
    2 Specify length of interconnecting control cable up to 50 feet.
    3 Specify Schweitzer 651R recloser control.
    4 Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 14.4 kV
  • Maximum Continuous Current: 630 A or 800 A
  • Maximum Interrupting Current (symmetrical): 10000 A RMS
  • load-interrupting current (asymmetrical): 42000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-651R Advanced Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frames and Extra creepage bushings
  • weight: 330 lbs. (150 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 600R Vacuum Recloser by selecting model number from the ratings table.
    2 Specify length of interconnecting control cable up to 50 feet.
    3 Specify Schweitzer 651R recloser control.
    4 Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 14.4 kV
  • Maximum Continuous Current: 630 A or 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical): 42000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-651R Advanced Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frames and Extra creepage bushings
  • weight: 330 lbs. (150 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 600R Vacuum Recloser by selecting model number from the ratings table.
    2 Specify length of interconnecting control cable up to 50 feet.
    3 Specify Schweitzer 651R recloser control.
    4 Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the Cypoxy® insulator, add “- E” to catalog number. Example: 199021-K030-E

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 8.5 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 8.5 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 8.5 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 11 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 11 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 11 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 8.5 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 8.5 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 8.5 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 11 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 11 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 11 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 30 A,RMS
  • Maximum Interrupting Current (symmetrical): 1250 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 50 A,RMS
  • Maximum Interrupting Current (symmetrical): 2000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground: 17 in.
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.

    This catalog number is with the Porcelain insulator. For with the polymer insulator, add “- P” to catalog number. Example: 99021-K030-P

Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More
Inquire
Compare for selected.
  • nominal voltage: 15 kV
  • Maximum Continuous Current: 100 A,RMS
  • Maximum Interrupting Current (symmetrical): 4000 A,RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Porcelain insulator and composite-polymer silicone insulator also available.
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: S&C’s new TripSaver Dropout Recloser, offered in system class voltage ratings of 15 and 25 kV, is ideally suited for lateral circuits that frequently experience momentary faults.

    TripSaver features an open-close-open-dropout operating sequence with a 5-second reclosing time interval. The interrupter resets five seconds after dropout, ready for the next operation. The first opening operation uses a very fast 1.5 to 3.5 cycle-clearing time. The second opening operation uses a time-current characteristic equivalent to either a “K” Speed or “T” Speed fuse curve. This operating sequence provides excellent coordination with the substation breaker and downstream transformer fuses.

    Unlike other single-phase reclosers, TripSaver requires no routine maintenance, field programming, or batteries for back-up power.
Read More