3 Phase,Hydraulic,Oil Intake 15kV

Compare and Learn about 3 Phase,Hydraulic,Oil Intake 15kV

Select up to 5 products from below to compare or request more information.

Kyle® Type Three-Phase Recloser

Cooper Power Systems

  • nominal voltage: 2.4 kV - 14.4 kV
  • Maximum Continuous Current: 100 A
  • Maximum Interrupting Current (symmetrical): 2000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator: As accesssories - Lockout-indicating switch provides remote indication of recloser lockout.
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
    • Lockout and Lockout Indication : Lockout-indicating switch, Shunt-lockout mechanism and Ground-fault lockout
    • Bushings: 17-in.-creepage bushings
  • weight:
    • Weight-dry : 236 lbs.
    • Weight-with oil : 394 lbs.
  • Finish/color: Heads are aluminum castings. Heavy-gage steel tanks are finished with an inhibiting epoxy prime coat and finish-coated with thermosetting acrylic paint. Finish color is light gray.
  • manufacturer's comment: Reclosers operate best when protected with surge arresters. On line applications, arrester protection is recommended on both sides of the recloser. If protection is to be provided on one side only, install the arrester on the source side. In substations, arresters are located on the load side. Cooper Power Systems distribution-class arresters provide excellent protection.
Read More
Inquire
Compare for selected.
  • nominal voltage: 2.4 kV - 14.4 kV
  • Maximum Continuous Current: 560 A
  • Maximum Interrupting Current (symmetrical): 10000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator: The remote lockout accessory enables an external control to trip the recloser and operate the lockout mechanism.
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
    • Automatic Tripping and Closing
    • Remote Operation and Indication
    • Low-Voltage Closing
    • Bushings and Terminals
  • weight: Weight-with oil : 785 lbs. (356 kg)
  • Finish/color: Heads are aluminum castings. Tanks are heavy-gage steel, finished with light gray polyester powder paint .
  • manufacturer's comment: Best operating results are achieved if reclosers are protected with surge arresters. On line applications, arrester protection is recommended on both sides of the recloser. (If protection is on one side only, it should be on the source side.) In substations, arresters should be on the load side. Cooper Power Systems distribution-class arresters provide excellent protection and are available with mounting brackets to fit Kyle reclosers
Read More