3 Phase,Electro,Vacuum Intake 25kV

Compare and Learn about 3 Phase,Electro,Vacuum Intake 25kV

Select up to 5 products from below to compare or request more information.
  • nominal voltage: 24.9 kV
  • Maximum Continuous Current: 630/800/1000/1200 A
  • Maximum Interrupting Current (symmetrical): 10000/12500/16000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Hydrophobic Cycloaliphatic Epoxy (HCEP)
  • Remote lockout indicator: Available
  • Standard bushing leakage distance to ground: 38.00 In. (960 mm)
  • Alternative bushing leakage distance to ground: 9.50 In. (240 mm)
  • Available factory installed accessories: Supported communications technologies include: Wi-Fi, Cellular, Radio, Ethernet, SCADA, 900 MHz Spread and Spectrum
  • weight: 333 lbs. (150 kg)
  • Finish/color: Amber
  • manufacturer's comment: Benefits are:
    • Compact, lightweight design is easy to install, maneuver, and transport
    • Cast aluminum or 304 stainless steel protects high and low voltage cabinets from the elements
    • Variety of mounting frames offers maximum fl exibility
    • No electronics in high voltage cabinet protects controls from thermal overload
    • Simple-to-operate controller for easy logic based programming, training, and maintenance
    • Front panel of PCD allows direct access to system currents, recloser status, and settings
    • Voltage sensing saves space by eliminating bulky potential transformers Up to four individually programmable reclose cycles (up to fi ve shots to lockout)
    • Communications equipment fi ts right in control cabinet
    • 24 hour / 7 day dependable customer support.
    Stainless enclosure with no electronics in the high voltage compartment for easy maintenance. Pole or substation mounted. Incorporates integrated voltage and current sensors, and virtually maintenance free magnetic actuators. The PCD control offers advanced capabilities such as adaptive protection, control monitoring, power quality, communications, single phase tripping, and loop control.
Read More
Inquire
Compare for selected.
  • nominal voltage: 24.9 kV
  • Maximum Continuous Current: 630/800/1000/1200 A
  • Maximum Interrupting Current (symmetrical): 10000/12500/16000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Hydrophobic Cycloaliphatic Epoxy (HCEP)
  • Remote lockout indicator: Available
  • Standard bushing leakage distance to ground: 38.00 In. (960 mm)
  • Alternative bushing leakage distance to ground: 9.50 In. (240 mm)
  • Available factory installed accessories: Supported communications technologies include: Wi-Fi, Cellular, Radio, Ethernet, SCADA, 900 MHz Spread and Spectrum
  • weight: 333 lbs. (150 kg)
  • Finish/color: Amber
  • manufacturer's comment: Benefits are:
    • Compact, lightweight design is easy to install, maneuver, and transport
    • Cast aluminum or 304 stainless steel protects high and low voltage cabinets from the elements
    • Variety of mounting frames offers maximum fl exibility
    • No electronics in high voltage cabinet protects controls from thermal overload
    • Simple-to-operate controller for easy logic based programming, training, and maintenance
    • Front panel of PCD allows direct access to system currents, recloser status, and settings
    • Voltage sensing saves space by eliminating bulky potential transformers Up to four individually programmable reclose cycles (up to fi ve shots to lockout)
    • Communications equipment fi ts right in control cabinet
    • 24 hour / 7 day dependable customer support.
    Stainless enclosure with no electronics in the high voltage compartment for easy maintenance. Pole or substation mounted. Incorporates integrated voltage and current sensors, and virtually maintenance free magnetic actuators. The PCD control offers advanced capabilities such as adaptive protection, control monitoring, power quality, communications, single phase tripping, and loop control.
Read More
Inquire
Compare for selected.
  • nominal voltage: 24.9 kV
  • Maximum Continuous Current: 400 A
  • Maximum Interrupting Current (symmetrical): 8000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: Optional contact Inputs and Outputs along with a choice of communication options, RS232, RS485, Fiber-Optic, and Ethernet, can be ordered as accessories. Mounting provisions can be provided to add customer-supplied radio and modem modules.
Read More
Inquire
Compare for selected.
  • nominal voltage: 24.9 kV
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight:
  • Finish/color:
  • manufacturer's comment: Optional contact Inputs and Outputs along with a choice of communication options, RS232, RS485, Fiber-Optic, and Ethernet, can be ordered as accessories. Mounting provisions can be provided to add customer-supplied radio and modem modules.
Read More
Inquire
Compare for selected.
  • nominal voltage: 24.9 kV
  • Maximum Continuous Current: 560 A
  • Maximum Interrupting Current (symmetrical): 12000 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?):
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
    • Low-Voltage Closing and Transfer Switch
    • Bushings and Terminals
    • Continuous Current Accessory
    • Hardware : Oil-level sight gauge
  • weight: Weight-with oil : 830 lbs.
  • Finish/color: Heads are aluminum castings. Tanks are heavygauge steel, finished with polyester powder paint (Munsell 5BG 7.0/0.4; light gray is the standard color).
  • manufacturer's comment: Best operating results are achieved if reclosers are protected with surge arresters. On line applications, arrester protection is recommended on both sides of the recloser. (If protection is on one side only, it should be on the source side.) In substations, arresters should be on the load side. Cooper Power Systems distribution-class arresters provide excellent protection and are available with mounting brackets to fit Kyle reclosers
Read More
Inquire
Compare for selected.
  • nominal voltage:
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Solid dielectric insulated
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight: Weight less bracket : 325 lbs. (148 kg).
  • Finish/color: Painted with a Munsell 7.0GY3.29/1.5 green finish.
  • manufacturer's comment:

    Applications

    • Sectionalizing schemes
    • Distributed automatic transfer
    • Distribution automation
    • Circuit breaker alternative
    • Relay protection
    • Revenue grade metering
    • Open bus ties
Read More
Compare or Request Quote for selected.
  • nominal voltage:
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Solid dielectric insulated
  • Remote lockout indicator:
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight: Weight (for a single phase module less bracket) : 125 lbs. (57 kg)
  • Finish/color: Painted with a Munsell 7.0GY3.29/1.5 green finish.
  • manufacturer's comment:

    Applications

    • Sectionalizing schemes
    • Distributed automatic transfer
    • Distribution automation
    • Circuit breaker alternative
    • Relay protection
    • Revenue grade metering
    • Open bus tie
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 6000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (Faultmaster 2500 Recloser Control, 351J Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame (9', 12', 15') and Extra creepage bushings
  • weight: 300 lbs. (136 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 300 Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2 Specify control cable length. 3 Specify Control: Faultmaster 2500 or 351 J
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 10000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (Faultmaster 2500 Recloser Control, 351J Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame (9', 12', 15') and Extra creepage bushings
  • weight: 300 lbs. (136 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 300 Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2 Specify control cable length. 3 Specify Control: Faultmaster 2500 or 351 J
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (Faultmaster 2500 Recloser Control, 351J Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame (9', 12', 15') and Extra creepage bushings
  • weight: 300 lbs. (136 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 300 Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2 Specify control cable length. 3 Specify Control: Faultmaster 2500 or 351 J
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 16000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (Faultmaster 2500 Recloser Control, 351J Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame (9', 12', 15') and Extra creepage bushings
  • weight: 300 lbs. (136 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 300 Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2 Specify control cable length. 3 Specify Control: Faultmaster 2500 or 351 J
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 6000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-351R Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame, Extra creepage bushings and Wildlife protectors
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: Long-Life Vacuum Interrupters provides twice (2x) the duty cycle required by ANSI C.37.60. When ordering and Specifying Information it is adviced to:
    1. Specify TriModä 300R Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Specify control cable length up to 100' (5' increments).
    3. Specify 351R Control. Consult factory for part number.
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 10000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-351R Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame, Extra creepage bushings and Wildlife protectors
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: Long-Life Vacuum Interrupters provides twice (2x) the duty cycle required by ANSI C.37.60. When ordering and Specifying Information it is adviced to:
    1. Specify TriModä 300R Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Specify control cable length up to 100' (5' increments).
    3. Specify 351R Control. Consult factory for part number.
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-351R Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame, Extra creepage bushings and Wildlife protectors
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: Long-Life Vacuum Interrupters provides twice (2x) the duty cycle required by ANSI C.37.60. When ordering and Specifying Information it is adviced to:
    1. Specify TriModä 300R Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Specify control cable length up to 100' (5' increments).
    3. Specify 351R Control. Consult factory for part number.
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 16000 A RMS
  • load-interrupting current (asymmetrical): 33000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-351R Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frame, Extra creepage bushings and Wildlife protectors
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: Long-Life Vacuum Interrupters provides twice (2x) the duty cycle required by ANSI C.37.60. When ordering and Specifying Information it is adviced to:
    1. Specify TriModä 300R Vacuum Recloser by selecting voltage class, continuous current, and interrupting current rating from the ratings table.
    2. Specify control cable length up to 100' (5' increments).
    3. Specify 351R Control. Consult factory for part number.
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 6000 A RMS
  • load-interrupting current (asymmetrical): 42000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-651R Advanced Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frames and Extra creepage bushings
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 600R Vacuum Recloser by selecting model number from the ratings table.
    2 Specify length of interconnecting control cable up to 50 feet.
    3 Specify Schweitzer 651R recloser control.
    4 Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 10000 A RMS
  • load-interrupting current (asymmetrical): 42000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-651R Advanced Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frames and Extra creepage bushings
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 600R Vacuum Recloser by selecting model number from the ratings table.
    2 Specify length of interconnecting control cable up to 50 feet.
    3 Specify Schweitzer 651R recloser control.
    4 Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 25 kV
  • Maximum Continuous Current: 630 or 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical): 42000 A
  • Insulation material (i.e. oil, air epoxy?): Solid High Dielectric Foam
  • Remote lockout indicator: Available (SEL-651R Advanced Recloser Control)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Arrester mounting bracket, Substation mounting frames and Extra creepage bushings
  • weight: 340 lbs. (154 kg)
  • Finish/color:
  • manufacturer's comment: When ordering it is adviced to:
    1 Specify TriModä 600R Vacuum Recloser by selecting model number from the ratings table.
    2 Specify length of interconnecting control cable up to 50 feet.
    3 Specify Schweitzer 651R recloser control.
    4 Select options and accessories
Read More
Compare or Request Quote for selected.
  • nominal voltage: 27 kV
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Sulphur Hexaflouride (SF6) Gas
  • Remote lockout indicator: Available (WSOS)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Mounting arrangement (Pole mount, Substation frame), Control cable, Concrete pole clamps and Bushing boots.
  • weight: 249 kg (with pole mount bracket)
  • Finish/color:
  • manufacturer's comment: Recloser can be mounted closer to pole if lightning arresters are pole mounted. Optional substation mounting frame available on request.
Read More
Compare or Request Quote for selected.
  • nominal voltage: 27 kV
  • Maximum Continuous Current: 800 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Sulphur Hexaflouride (SF6) Gas
  • Remote lockout indicator: Available (WSOS)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Mounting arrangement (Pole mount, Substation frame), Control cable, Concrete pole clamps and Bushing boots.
  • weight: 249 kg (with pole mount bracket)
  • Finish/color:
  • manufacturer's comment:

    The Nu-Lec Industries automatic circuit reclosers provide many outstanding advantages to the user. New and innovative features have been made possible by the intimate way the pole mounted circuit breaker and control cubicle work together.

    WSOS is the Nu-Lec Industries Switchgear Operating System software based on Microsoft Windows®. It provides easy access to all switchgear functions from opening/closing, through configuring protection and communication parameters to accessing measurement and analytical data. By using a desktop or portable PC engineers can manage a large number of reclosers either remotely via a communications link or locally via a serial port or Ethernet connection.

Read More
Compare or Request Quote for selected.
  • nominal voltage: 27 kV
  • Maximum Continuous Current: 630 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Cyclo-aliphatic Epoxy Bushings
  • Remote lockout indicator: Available (WSOS)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories:
  • weight: Recloser tank: 118kg
    Control Cubicle and Sundry items:145kg
  • Finish/color:
  • manufacturer's comment: Optional substation mounting frame available on request. Connections are made to the bare recloser terminals using crimp lugs, parallel groove clamps or stud connectors. This arrangement is suitable for connection into an insulated or bare conductor system, as appropriate.
Read More
Compare or Request Quote for selected.
  • nominal voltage: 27 kV
  • Maximum Continuous Current: 630 A
  • Maximum Interrupting Current (symmetrical): 12500 A RMS
  • load-interrupting current (asymmetrical):
  • Insulation material (i.e. oil, air epoxy?): Cyclo-aliphatic Epoxy Bushings
  • Remote lockout indicator: Available (WSOS)
  • Standard bushing leakage distance to ground:
  • Alternative bushing leakage distance to ground:
  • Available factory installed accessories: Mounting arrangement (Pole mount, Substation frame), Control cable and Concrete pole clamps
  • weight: 146 kg (with pole mount bracket)
  • Finish/color:
  • manufacturer's comment: WSOS is the Nu-Lec Industries Switchgear Operating System software based on Microsoft Windows®. It provides easy access to all switchgear functions from opening/closing, through configuring protection and communication parameters to accessing measurement and analytical data. By using a desktop or portable PC engineers can manage a large number of reclosers either remotely via a communications link or locally via a serial port or Ethernet connection.
Read More
Compare or Request Quote for selected.
Select up to 5 products from above to compare or request more information.

Tags: