Polymer Station Arresters

Compare and Learn about Polymer Station Arresters

Showing 50 of 634 products.
Select up to 5 products from below to compare or request more information.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 3 kV
  • maximum continuous operating voltage (mcov): 2.55 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 8.4 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 7.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 6 kV
  • maximum continuous operating voltage (mcov): 5.1 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 16.7 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 14.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 9 kV
  • maximum continuous operating voltage (mcov): 7.65 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 25 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 21.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 10 kV
  • maximum continuous operating voltage (mcov): 8.4 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 27.8 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 23.5 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 18 kV
  • maximum continuous operating voltage (mcov): 15.3 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 50.1 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 42.3 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 36 kV
  • maximum continuous operating voltage (mcov): 29 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 95.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 81 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 39 kV
  • maximum continuous operating voltage (mcov): 31.5 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 104.2 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 88 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 45 kV
  • maximum continuous operating voltage (mcov): 36.5 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 120.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 102.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 48 kV
  • maximum continuous operating voltage (mcov): 39 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 128.7 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 108.7 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 54 kV
  • maximum continuous operating voltage (mcov): 42 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 144.4 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 122 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 60 kV
  • maximum continuous operating voltage (mcov): 48 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 163.5 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 138 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 72 kV
  • maximum continuous operating voltage (mcov): 57 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 191.8 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 162 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 90 kV
  • maximum continuous operating voltage (mcov): 70 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 241.8 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 204.2 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 96 kV
  • maximum continuous operating voltage (mcov): 76 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 257.4 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 217.4 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 108 kV
  • maximum continuous operating voltage (mcov): 84 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 288.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 244 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 108 kV
  • maximum continuous operating voltage (mcov): 88 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 288.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 244 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 120 kV
  • maximum continuous operating voltage (mcov): 98 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 326.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 276.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 132 kV
  • maximum continuous operating voltage (mcov): 106 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 352 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 298 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 144 kV
  • maximum continuous operating voltage (mcov): 115 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 386.1 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 326.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 168 kV
  • maximum continuous operating voltage (mcov): 131 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 445 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 380 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 172 kV
  • maximum continuous operating voltage (mcov): 140 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 455 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 389 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 180 kV
  • maximum continuous operating voltage (mcov): 144 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 476 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 407 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 192 kV
  • maximum continuous operating voltage (mcov): 152 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 508 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 434 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 228 kV
  • maximum continuous operating voltage (mcov): 180 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 604 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 516 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 27 kV
  • maximum continuous operating voltage (mcov): 22 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 72.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 61.6 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 30 kV
  • maximum continuous operating voltage (mcov): 24.4 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 80.4 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 67.9 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 21 kV
  • maximum continuous operating voltage (mcov): 17 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 56.3 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 47.6 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 24 kV
  • maximum continuous operating voltage (mcov): 19.5 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 63.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 54 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 12 kV
  • maximum continuous operating voltage (mcov): 10.2 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 33.3 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 28.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.

DynaVar® PVN Polymer Housed Station Class Arrester

Ohio Brass (Hubbell Power Systems)

  • class (recognized by ieee c62.11) : ANSI/IEEE Standard C62.11-1999
  • duty-cycle rating : 15 kV
  • maximum continuous operating voltage (mcov): 12.7 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 41.7 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 35.2 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 3 kV
  • maximum continuous operating voltage (mcov): 2.55 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 8.5 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 7.4 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 6 kV
  • maximum continuous operating voltage (mcov): 5.1 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 16.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 14.8 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 9 kV
  • maximum continuous operating voltage (mcov): 7.65 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 25.3 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 22.2 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 10 kV
  • maximum continuous operating voltage (mcov): 8.4 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 27.6 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 24.2 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 12 kV
  • maximum continuous operating voltage (mcov): 10.2 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 33.5 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 29.4 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 15 kV
  • maximum continuous operating voltage (mcov): 12.7 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 42.2 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 37 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 18 kV
  • maximum continuous operating voltage (mcov): 15.3 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 50.5 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 44.3 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 21 kV
  • maximum continuous operating voltage (mcov): 17 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 55.3 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 48.5 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 24 kV
  • maximum continuous operating voltage (mcov): 19.5 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 67 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 58.8 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 27 kV
  • maximum continuous operating voltage (mcov): 22 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 75.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 66.6 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 30 kV
  • maximum continuous operating voltage (mcov): 24.4 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 82.9 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 72.7 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 36 kV
  • maximum continuous operating voltage (mcov): 29 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 101 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 88.2 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 39 kV
  • maximum continuous operating voltage (mcov): 31.5 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 105.8 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 92.8 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 45 kV
  • maximum continuous operating voltage (mcov): 36.5 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 122.3 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 107.3 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 48 kV
  • maximum continuous operating voltage (mcov): 39 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 134 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 117.5 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 54 kV
  • maximum continuous operating voltage (mcov): 42 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 144 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 126.3 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 60 kV
  • maximum continuous operating voltage (mcov): 48 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 161.6 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 141.7 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) :
  • duty-cycle rating : 72 kV
  • maximum continuous operating voltage (mcov): 57 kV
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave: 195 kV
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 171.1 kV
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: ESP silicone alloy weathershed material
  • housing material/hanger bracket color:
Read More
Compare or Request Quote for selected.
  • class (recognized by ieee c62.11) : Station Class
  • duty-cycle rating :
  • maximum continuous operating voltage (mcov): 144 kV rms
  • maximum front-of-wave voltage cresting in 0.5 microseconds for 10 ka wave:
  • Maximum Discharge Voltage for 8 X 20 Microsecond 5 kA Wave: 390 kV peak
  • maximum discharge voltage for 8 x 20 microsecond 20 ka wave:
  • housing material: silicone
  • housing material/hanger bracket color: grey
Read More
Inquire
Compare for selected.
Select up to 5 products from above to compare or request more information.
Showing 50 of 634 products.

Tags:

Please Login or Register to Create Tags